patient monitor

patient monitor
Product Detailed
PATIENT MONITORype Arrhythmic Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S_T segment analysis,

PATIENT MONITOR 

1.20 Type Arrhythmic Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titration table

2. Efficient resistance to interference of defibrillator and electrosurgical cautery

3. SPO2 can testing for 0.1% Weak

4. RA-LL impedance Respiration

5. Trend Coexist Display

6. OxyCRG DyNamic View Display

7. Bed to Bed view Display

8. Networking capacity and nurse_calling system

9. Options of printing, IBP, VGA and EtCO2.

10. UP to 4 hours working capacity of built_in rechargeable battery.

11, 12.1"high resolution color TFT LCD display.

12, Large volume of tabular and graphic trends information storage and easy to recall.

13, Anti-ESU, anti- defibrillator

14, 6 Standard parameters:ECG,RESP,NIBP,SPO2,1_TEMP,PR/HR.

15, Capture dynamic waveforms.

Product Specification

Lead Mode: 5 Leads (    R, L, F, N, C or RA, LA, LL, RL,V)

Lead selection: I, II, III, avR, avL, avF, V,

Waveform: 2 ch

Lead mode: 3 Leads ( R, L, F or RA, LA, LL)

Lead selection: I, II, III,

Waveform: 1 ch

Gain: ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV,  auto

HR and Alarm       

Range    

Adult: 15 ~ 300 bpm

Neo/Ped: 15 ~ 350 bpm

Accuracy       : ± 1% or ± 1bpm,which great

Resolution: 1 bpm

Sensitivity: > 200 (uV P-P)

Differential Input Impedance: > 5 MΩ

CMRR

Monitor: > 105 dB

Operation: > 105 dB

Diagnosis: > 85 dB

Electrode offset potential: ±300mV

Leakage Current: < 10 uA

Baseline Recovery: < 3 S  After Defi.

ECG Signal Range: ±8 m V ( Vp-p )    

Bandwidth  

Surgery: 1 ~ 15 Hz

Monitor: 0.5 ~ 35 Hz

Diagnostic: 0.05 ~ 100 Hz

Calibration Signal: 1 (mV p-p),  Accuracy:±5% 

ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting      

Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

Alarm: Available

Review: Available

ARATION

Method: Impedance between R-F(RA-LL)

Differential Input Impedance: >2.5 MΩ

Measuring Impedance Range:       0.3~5.0Ω

Base line Impedance Range: 0 2.5  KΩ

Bandwidth: 0.3 ~ 2.5 Hz

Resp. Rate

Measuring and Alarm Range 

Adult: 0 ~ 120 rpm

Neo/Ped: 0 ~ 150 rpm

Resolution: 1 rpm

Accuracy       : ±2 rpm

Apean Alarm: 10 ~ 40 S

Mode: Manual, Auto, STAT

Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)

Measuring Period in STAT Mode: 5 Min

Pulse Rate Range: 40 ~ 240 bpm

Alarm Type: SYS, DIA, MEAN

Measuring and alarm range                 

  Adult Mode

SYS: 40 ~ 270 mmHg

DIA: 10 ~ 215 mmHg

MEAN: 20 ~ 235 mmHg

  Pediatric Mode

SYS: 40 ~ 200 mmHg

DIA: 10 ~ 150 mmHg

    MEAN:20 ~ 165 mmHg

Neonatal Mode

SYS: 40 ~ 135 mmHg

DIA:10 ~ 100 mmHg

MEAN:20 ~ 110 mmHg

Resolution Pressure:1mmHg

Accuracy       Pressure  Maximum Mean error: ±5mmHg

Maximum Standard deviation: ±8mmHg

Overpressure Protection

Adult Mode: 297±3 mmHg

Pediatric Mode: 240±3 mmHg

Neonatal Mode: 147±3 mmHg

Alarm Range: 0 ~ 100 %

Resolution: 1 %

Accuracy       : 70% ~ 100% ±2 %

     0% ~ 69% unspecified

Actualization interval: about 1 Sec.

Alarm Delay: 10 Sec.

Pulse Rate

Measuring and Alarm Range: 20~300bpm

Resolution: 1bpm

Accuracy       : ±2bpm

Channel: 1

Measuring and Alarm Range: 0 ~ 50 °C

Resolution: 0.1°C

Accuracy       : ±0.1°C

Actualization interval: about 1 Sec.

Average Time Constant:<10 Sec.

Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range

ART: 0 ~ 300 mmHg

       PA: -6 ~ 120 mmHg

       CVP/RAP/LAP/ICP: -10 ~ 40 mmHg

       P1/P2: -10 ~ 300 mmHg                                  

Press Sensor

Sensitivity: 5 uV/V/mmHg

Impedance: 300-3000Ω

Resolution: 1 mmHg

Accuracy       : ±2% or ±1mmHg, which great

Actualization interval: about 1 Sec.